Sign in →

Test Code PRTYSC Type and Screen, Pre-Admit

Additional Codes

EPIC LAB4901

Purpose

Pre-admit testing is performed for blood bank when surgery is within 2 weeks and the patient has not been pregnant or transfused in the last 90 days. This allows testing to be performed in advance to decrease delay on day of surgery.

Methodology

Hemagglutination by MTS gel card system and/or manual tube method.

Sample Type

Preferred Sample Type
Pink top

Centrifuge: Yes (In Blood Bank)

 

Each tube needs to be properly labeled with a chart label/barcode label AND a crossmatch sticker (Blood band sticker). All identifying information on the requisition must be identical to information on the specimen tube. This is a strict safety requirement, NO EXCEPTIONS.

Specimen Minimum Volume

1 mL

Specimen Stability

Temperature Time
Ambient (18-25°C)  
Refrigerated (2-8°C) (store)  
Frozen (-15 to -20°C) Do no freeze

Result Reporting

Blood Type 

 ABO Blood Typing
Antisera / Patient Cells Reaction Forward Type Reagent Cells / Patient Serum Reaction Reverse Type
Anti-A Anti-B A1 Cells B Cells
0 0 O (+) (+) O
(+) 0 A 0 (+) A
0 (+) B (+) 0 B
(+) (+) AB 0 0 AB

 

Antibody Screen

Reaction Antibody Screen
0  (No agglutination) Negative
1+ or greater agglutination Positive*

*Antibody panels are performed on all positive screens for antibody identification

Rejection Criteria

  • Samples outside of stability limits
  • Samples not properly labled (2 patient identifiers & blood band sticker required)
  • Samples submitted without blood band
  • Surgery date >2 weeks away
  • Pregnancy or transfusion within last 90 days

Availability

Performed STAT
24/7 No

 

Performing Laboratory

MultiCare Yakima Memorial Hospital Laboratory

Lab Department

Blood Bank

CPT Code

86900

86901

86850

LOINC

34532-2 Blood Type and Indirect antibody screen panel (Bld)